Fanuc 10t Parameter Manual @ideacnc    โทรด่วน  097-195-4845

CAD CAM Wire Cut MaCRO Wire

Sets the I/O channel (usually set to 0 or 1 for the main RS-232 port).

Parameters are categorized into blocks. For example, 5000-series parameters usually handle axis data, while 9000-series parameters often control system options and macro program locking.

The control system is a classic, robust CNC controller designed for turning centers (lathes). Despite the advent of newer, faster controls, the Fanuc 10T remains operational in countless manufacturing facilities worldwide, known for its reliability and precision. However, maintaining, diagnosing, and optimizing this machine requires intimate knowledge of its parameter system.

Press the SETTING function key on the CRT panel.

| Problem Description | Likely Cause / Solution (Parameter to Check & Adjust) | Required Preconditions | | :--- | :--- | :--- | | | This is often a parameter mismatch. Set #0020 (I/O Channel) to 1 or 2 , and set #5110 (Device) to 1 , #5111 (Stop Bits) to 2 , #5112 (Baud Rate) to a value like 10 (4800 baud). | PWE=1 | | Spindle Won't Orient or Thread | A technician may have disabled the spindle encoder to keep the machine running. Check parameter #5603 . If the bit on the far left (bit 7) is a 1 , set it to 0 to re-enable encoder feedback. | PWE=1 | | Machine Moves on Screen Only (Simulation Mode) | The Machine Lock (MLK) or Auxiliary Function Lock (AFL) signals might be on. Check diagnostic address G104 . If G104.0 (AFL) or G104.7 (MLK) shows a 1 , set it to 0 to regain control of the physical machine. | Diagnosis Mode | | Turret Jams / Indexes Incorrectly | If the turret keeps spinning or skips tools, the PMC (PC) data table settings (e.g., D108 for # of tool stations) are often wrong. The issue is not a CNC axis parameter. | PMC Maintenance Mode | | G71/G72 Canned Cycle Retract Crash | The default back-off amount is set by parameter #6215 . For small boring bars, change this from .1" (or metric equivalent) to a much smaller value, such as .015" . | PWE=1 | | Unable to Edit 9000 Macro Programs | Setting PWE=1 is not enough. You must also set parameter #2201, bit 0 (NE9) to 1 . This is a separate security lock for program-level macros. | PWE=1 |

Cycle the main power to the machine to initialize the new settings. Conclusion and Best Practices

Hunting for the Fanuc 10T Parameter Manual? It isn’t just a PDF; it’s the keys to the kingdom. Here is why you need it, where to find it (legally), and the three golden rules before you change a single bit.

สร้างเว็บไซต์สำเร็จรูปฟรี ร้านค้าออนไลน์